The new ETA assessment in concrete confirms the durability of the injection mortar even with an extended service life of 100 years instead of the usual 50 years under both normal and seismic loading. This is not only a significant contribution to sustainability but is also of particular importance to infrastructure projects designed for a long service life..










| Temperatures in the anchoring base | Maximum gelling time | Minimum curing time | ||
|---|---|---|---|---|
| FIS V Plus | FIS VW Plus High Speed | FIS V Plus | FIS VW Plus High Speed | |
| -10 to -5°C | - | - | - | 12 hrs. |
| > -5 to 0°C | - | 5 min. | 24 hrs. | 3 hrs. |
| > 0 to +5°C | 13 min. | 5 min. | 3 hrs. | 3 hrs. |
| > +5 to +10°C | 9 min. | 3 min. | 90 min. | 50 min. |
| > +10 to +20°C | 5 min. | 1 min. | 60 min. | 30 min. |
| > +20 to +30°C | 4 min. | - | 45 min. | - |
| > +30 to +40°C | 2 min. | - | 35 min. | - |